Wrh r or, Rh w c, Gor r – ritetemp 8050C User Manual
Page 7: 2 wire, 3 wire
PG
11
PG
12
Go To Page 10
STEP 1 - Connect the R (or RH) wire to the RH terminal on the
thermostat. This connects to the Heater Power.
STEP 2 - Connect the W wire to the W terminal on the thermostat. This
connects the heater control line to the thermostat.
Your heater is now connected to the thermostat.
STEP 1 - Connect the R (or RH) wire to the RH terminal on the
thermostat. This connects to the Heater Power.
STEP 2 - Connect the W wire to the W terminal on the thermostat.
This connects the heater control line to the thermostat.
STEP 3 - Connect the G wire to the G terminal on the thermostat.
This connects the Fan to the thermostat.
Your system is now connected to the thermostat.
Go To Page 10
NOTE: Wires marked with
the dotted line are optional.
NOTE: Wires marked with
the dotted line are optional.
W
RH
R
or
From Furna
ce
C
RH
W
C
From Furna
ce
G
or R
2 WIRE
jumper
wire
FURNACE
HEAT
Thermostat
R
W
C
HEAT
Power
3 WIRE
FURNACE
jumper
wire
Heat
Power
Heat
W
G
RH
C
FAN
Thermostat