beautypg.com

Regal Ware W15120 User Manual

Page 8

background image

baffle, flat side down into the spout and
secure with the nut. The hole on the flat
side of the baffle should be facing down.
It is important that you tighten the
securing nut, with baffle properly in
place, onto the boiling chamber before
each use. Failure to properly secure the
baffle and nut may result in leakage or
early shut off of the AquaVié

unit.

7. Wipe off any water on the outside and

bottom of the boiling chamber and around
the electrical connection.

8. Slide the boiling chamber into the chassis

and press firmly to ensure that it is properly
placed. It is important that the boiling
chamber be pressed firmly into the chassis. It
is recommended that you place one hand on
the back of the chassis and push the boiling
chamber into the chassis with the other
hand. To ensure that a tight electrical
connection is made, also press on the base
of the boiling chamber near the start
button.

CAUTION: To prevent personal injury or
property damage the boiling chamber must
be fully engaged prior to start-up.

9. Press the “start” button at the base of the

boiling chamber.

NOTE: The button will glow when the boiling
chamber is heating; however, the light will go
out, and the boiling chamber will stop heating
if electrical power to the boiling chamber is
interrupted or stopped. If this occurs, press the
start button again to restart the cycle.

10. The cooling fan will not start immediately.

A delayed fan startup feature has been included
in your AquaVié

system. The fan will start once

the boiling chamber has reached a pre-determined
temperature, approximately 30-40 minutes after
starting the cycle.

-5-

Flat edge
of baffle

Securing

Nut

Spout

Baffle

Dispensing

Valve

Mineral

Dispenser

Flat

Gasket

O-Ring

Start

Button