Rinnai RHFE-431FA User Manual
Page 9
– 7 –
Safety Devices
Noise Level Range
HI
LOW
38
32dB(A)
TYPE
SPECIFICATIONS FOR VENT SIZES
S
Thin Walls Mobile Home
Wood Walls
Wood/Brick
Brick/Block
Special
3"
4 1/2"
(75
115)mm
4 1/2"
9 1/2"
(115
240 )mm
9 1/2"
15 3/4"
(240
400 )mm
15 3/4"
23 5/8"
(400
600 )mm
23 5/8"
31 1/2"
(600
800 )mm
A
B
C
D
(80mm) 3 1/8"
(4m, 2 bends)
13ft., 2 bends
Combustion Method
Air Supply Exhaust
Radiation Method
Forced combustion
Closed Type
Forced convection
Wall Penetration
Hole
Max. Extended
AIR SUPPLY/
EXHAUST PIPE
Flame failure – Flame rod
Over heat – Bi-metal switch, thermal fuse, thermistor
Power failure – PCB
Power surge – 3 Amp. fuse
Fan delay – Micro computer timer
Pre-purge – Combustion fan, pre-purge timer, spark sensor
Room over heat – Automatic cut off at 104°F after 10 minutes
** BTU - Efficiency increase with vent size. Clearances from combustibles see pages 3 and 19.
** Thermal efficiency rating determined under continuous operating conditions, and was determined
independently of any installed system.