beautypg.com

Rinnai RU80E User Manual

Page 2

background image

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us

MC-91-2 (included)
Deluxe controller: MC-100V-1US (optional)
Bathroom controller: BC-100V-1US (optional)
MCC-91-2 (optional; for hydronic and commercial applications)

Non-polarized two-core cable, minimum 22 AWG

• Flame failure - Flame Rod
• Boiling protection

• Combustion fan rpm check
• Over current - glass fuse
• Top of heater - 12 inches

• Front (Panel) - 24 inches
• Front (Exhaust) - 24 inches
• Top of heater - 2 inches

• Front (Panel) - 0 inches *
• Front (Exhaust) - 24 inches

Natural Gas: min 5” W.C.

max 10.5” W.C.

Propane Gas: min 8” W.C.

max 13.5” W.C.

Natural Gas: high fire 1.9” W.C. low fire 0.46” W.C.
Propane Gas: high fire 2.1” W.C. low fire 0.50” W.C.

Complies with South Coast Air Quality Management District 14 ng/J or
20 ppm NOx emission levels

DIMENSIONS

WEIGHT: 70.5 lb (32 kg)

Controller




Controller Cable

Safety Devices


Clearances from Combustibles


Clearances from Non-combustibles

* 24 inches required for serviceability


Min. / Max. Gas Supply Pressure


Manifold Gas Pressure (inches W.C.)


NOx

• Remaining flame (OHS)

• Thermal fuse
• Automatic frost protection

• Back of heater - 0 inches
• Bottom of heater - 12 inches
• Sides of heater - 6 inches
• Back of heater - 0 inches

• Bottom of heater - 2 inches
• Sides of heater - 1/8 inch

DIM Inches

(mm)

A (GAS)

1.6 (40.2)

A (COLD)

2.0 (50.2)

A (HOT)

1.6 (41.2)

A (CONDENSATE

OUTLET)

0.9 (22.4)

B 5.0

(127.2)

C 1.9

(47.8)

D 0.52

(13.3)

B

C

I

J

D

E

F

G

H

K

10.1 (257.5)

28.4 (721.

6)

25.7 (654

)

8.7 (222)

A

0.4 (10.1)

0.6 (15)

18.5 (470)

10.0 (253.8)

0.6 (15)

2.0 (50)

RU80e (KB2530WD)

DIM Inches

(mm)

E 2.2

(56.3)

F 2.3

(58.3)

G 5.0

(127.2)

H 2.0

(50)

I 3.0

(76)

J 7.1

(179)

K 18.3

(466)

Heat exchanger: 12 years* for residential, 10 years for residential and space heating, and 5 years* for
commercial; All other parts: 5 years*; Labor: 1 year;
(* 3 years if used as a circulating water heater within a circulation loop, when the water heater is in
series with a circulation system and all circulating water flows through the water heater, and where an
aquastat / thermostat, timer, or an on-demand recirculation system is not incorporated.)
Refer to the manual for complete warranty information.

Limited