3 rollers not running, Causes, Measures – Royal Sovereign RSL-2701 User Manual
Page 10
2.3 Rollers Not Running
1. Safety cover is not in proper position.
2. Wire-Motor's connector is disconnected.
3. Film is jammed on the rollers.
4. Main PCB is defective.
5. Main motor is defective.
Before troubleshooting, be sure to disassemble
the Right cover ,the Left cover and the Rear cover.
Refer to how to replace each component for the
disassembly of them.
1. Safety cover is not in proper position.
1) Make the edge of Safety Cover to press
the lever of Micro Switch completely.
Check if the Motor wire connectors are
connected correctly.
CAUSES
8
2. Motor wire connectors are disconnected.
MEASURES
MICRO
SWITCH
edge of safety cover
WIRE-
MOTOR