2.3 Rollers Not Running

1. Safety cover is not in proper position.

2. Wire-Motor's connector is disconnected.

3. Film is jammed on the rollers.

4. Main PCB is defective.

5. Main motor is defective.

Before troubleshooting, be sure to disassemble

the Right cover ,the Left cover and the Rear cover.

Refer to how to replace each component for the

disassembly of them.

1. Safety cover is not in proper position.

1) Make the edge of Safety Cover to press

the lever of Micro Switch completely.

Check if the Motor wire connectors are

connected correctly.

CAUSES

8

2. Motor wire connectors are disconnected.

MEASURES

MICRO

SWITCH

edge of safety cover

WIRE-

MOTOR

This manual is related to the following products: