beautypg.com

Runco VX-5000ci User Manual

Page 37

background image

35

COMMAND

PARAMETER

(min/max)

Value stored?

DESCRIPTION

!STORE

NA

YES

Stores the current set of values
(all values) into non-volatile
memory

!RESTORE

NA

YES

Restores the stored values

!FACTORY

NA

YES

Restores all values to factory
default levels

!STATUS

NA

NA

Asks the Controller to provide
the hardware information,
current values and system status
to the automation system

!RESTART

NA

NO

Restarts the DHD Controller
(same as turning it on and off)

!ECHO

NA

NO

Enables the Controller to echo
back commands and values to
the automation system

!NOECHO

NA

NO

Disables the Controller's
character echoing

!INSTALLMODEOFF

NA

NA

Disables the Installation menu
(removes it from the main menu)

!INSTALLMODEON

NA

NA

Enables the Installation menu
(enables it on the main menu)

!SERVICEMODEON

NA

NA

Enables the service mode

!SERVICEMODEOFF

NA

NA

Disable the service mode

RGAIN

-30/30

NO

Adjust the Red level of image

GGAIN

-30/30

NO

Adjust the Green level of image

BGAIN

-30/30

NO

Adjust the Blue level of image

ROFFSET

-30/30

NO

Adjust the Red level of image

GOFFSET

-30/30

NO

Adjust the Green level of image

BOFFSET

-30/30

NO

Adjust the Blue level of image

RGamma

-30/30

NO

Adjust the Red gamma of image

GGamma

-30/30

NO

Adjust the Green gamma of
image

BGamma

-30/30

NO

Adjust the Blue gamma of image

IRCODE

013

NO

Changes the IR Code Set of the
Controller to 013

IRCODE

215

NO

Changes the IR Code Set of the
Controller to 215

IRCODE

510

NO

Changes the IR Code Set of the
Controller to 510

IRCODE

918

NO

Changes the IR Code Set of the
Controller to 918

IRCODE

0

NO

Disables the IR receiver