Specification data – Rheem 136-1826 User Manual
Page 4

MBH Natural Gas
Sanimaster
Typhoon
(Indoor)
(Outdoor)
Input
Output Input Output
136.0 112.0 136.0 112.0
181.0 148.0 181.0 148.0
264.0 216.0 264.0 216.0
334.0 274.0 334.0 274.0
399.0 327.0 399.0 327.0
511.5 419.4 511.5 419.4
627.0 514.0 627.0 514.0
726.0 595.0 726.0 595.0
825.0 676.5 825.0 676.5
926.0 759.0
961.7 788.6
1083.0 888.0
1124.7 922.0
1178.0 966.0
1222.5 1002.4
1287.0 1055.0
1336.6 1096.0
1413.0 1158.5
1467.0 1203.0
1570.0 1287.0
1630.0 1336.6
1758.0 1441.5
1825.6 1497.0
ELECTRICAL RATINGS
Model
Size
With Pump
136-264 3.4 amps @ 120V(1/8 hp pump)
331-399 3.6 amps @ 120V(1/6 hp pump)
512-1826 7.9 amps @ 120V (1/2 hp
pump)
MBTUH PROPANE GAS†
Model
Size
Multiplier
136-399
Same as natural gas
512-825
.94
926-1826
.92 Indoor
.955 Outdoor (Input)
.92 Outdoor (Output)
† Multiplier x Nat. MBTUH =
Pro. MBTUH
MODEL
136
181
264
331
399
512
627
726
825
926
962
1083
1125
1178
1223
1287
1337
1413
1467
1570
1630
1758
1826
STYLE
In-
Out-
Door
Door
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Rated inputs are suitable for up to 2000 feet elevation. For elevations above 2000 feet, reduce input 4% for each
1000 feet above sea level. These heaters are tested and certified to ANSI Standard Z 21.10.3
SPECIFICATION DATA
4