Panel Descriptions

REAC Ports 1–10

You can connect the master REAC device to the desired REAC port and split its output to
other REAC ports.

REAC ports 3 to 10 are compatible with REAC EMBEDDED POWER, and can supply power
to devices compatible with REAC EMBEDDED POWER.

When a REAC device is connected, the system automatically detects whether the device is
compatible with REAC EMBEDDED POWER and supplies power if compatible.

Power is not supplied if the device is not compatible with REAC EMBEDDED POWER.

POWER/LINK/ACT Indicators

These indicate the status of the ports. The indicators function as follows.

POWER Indicator

Powering up the unit makes the POWER indicator light up.

[POWER] Switch

This switches the power on and off.

Front Panel

Status

Indicator

Red

(POWER)

Green
(LINK)

Yellow

(ACT)

With nothing connected

Off

Off

Off

When supplying power to a REAC EMBEDDED POWER device

Lit

When enabled for transmission

Lit

Lit

When communicating with another REAC device

Flashing

Lit

• Never connect any equipment

other than REAC devices to

REAC ports 3 through 10.

• REAC ports 1 and 2 do not

support REAC EMBEDDED

POWER.

Connect devices compatible

with REAC EMBEDDED POWER

to REAC ports 3 through 10.

S-4000D_e.book 7 ページ 2009年5月25日 月曜日 午前11時46分