Settable, Indicator table, Specifications – Rosewill Power Protection UPS RU-103 User Manual

Page 2: Troubleshooting

background image

Power Protection UPS

RU103 User Manual

7.

USB Communication Port

The built-in USB port connects to your computer. The PowerGuard Smart

monitoring and shutdown software provided can automatically save your files

and shut down your computer in the event of a prolonged power outage. The

software also provides information regarding the status of your utility power

line

Installing software




If autoplay is not enabled on the computer, please follow instructions below:

‧Double-click on My Computer on the desktop.

‧Double-click on the CD-ROM drive icon and follow the on-screen

instructions.


8.

Data /Phone/Fax Protection Connectors


9.

“Surge Only” Outlets

Four Nema 5-15R output receptacles that will provide surge and spike

protection only


10.

“Battery & Surge” Outlets

Four Nema 5-15R output receptacles that will provide both battery backup and

surge protection.


11.

AC Input Power Cord

Plug the AC power cord into your power source


12.

Coax in :

TV/TNT/Satellite reception protection

13.

Circuit Breaker (re-

settable

)

The button will protrude when the overload condition occurs. If the button

protrudes, disconnect some non-essential equipment and reset the circuit

breaker by pushing the button inward.


14.

Coax out:

TV/TNT/Satellite reception protection

INDICATOR TABLE

Status Indicators

The UPS provides both visual and audible status indicators. Visual indicators consist
of three LEDs to represent the following conditions:

On utility power operation

On battery power operation

UPS fault/alarm

LED and Alarm Indicator Table

UPS Status

Green

LED

Red LED

Yellow

LED

Alarm

Self-test Blink

1

B1

Normal On

X

X

X

Self Low

battery

On Blink2 X

B5

AC mode

( on utility)

overload On Blink2

X

B2

Normal X

X

On

B1

Low

battery

X X

Blink2 B3

DC mode

( on battery)

Overload X Blink2 On

B2

Short/Fault mode

X

On

X

On

Over-Bat/Bat Fault

X

Blink2

X

B4

* Blink 1 : ON 0.5 seconds / OFF 1 seconds

* Blink 2 : ON 0.25 seconds / OFF 0.25 seconds

* B1: 1 beep / 5 seconds: ON 0.25 seconds / OFF 4.75 seconds

* B2: 1 beep / 0.5 seconds :ON 0.25 seconds / OFF 0.25 seconds

* B3 : 2 beeps / 5 seconds: ON 0.25 seconds / OFF 0.25 seconds 2 times, 4 seconds OFF

* B4 : 3 beeps / 5 seconds: ON 0.25 seconds / OFF 0.25 seconds 3 times, 3.5 seconds OFF

* B5: 3beeps / 30seconds :ON 0.25 seconds / OFF 0.25 seconds 3 times, 28.5seconds OFF

Recycling Information:

Your UPS contains Non-Spill Sealed Lead Batteries. On the battery you will

find the battery name. Please reference the chart below for recycling

information. Other brand(s) of battery please contact Rosewill.com.

Battery Name

Recycling inside the USA

Vision Battery

1-877-730-2877

First Power Battery

1-877-730-2877

BB Battery

1-800-278-8599

Follow the on-screen
instructions

.

SPECIFICATIONS

Model

RU-103

Capacity

1500 VA / 900W

Nominal Input Voltage

120 Vac

Nominal Output Voltage

120 Vac

Automatic Voltage
Regulation (AVR)

108-130Vac(±3%)

Frequency

50 / 60 Hz auto sensing

8 Outlets (4 Battery Backup & Surge Protection;

4 Surge Protection only)

Outlets

Lighting / Surge Protection

320 Joules

Transfer time to Battery/AC

2-6ms typical

Battery Type

Maintenance free lead-acid battery

(2)* 12V 9 Ah

Battery Specification

Typical Backup Time

4-7 Minutes

RJ11/45

LAN / Phone / Fax Protection

Short Circuit Protection

Circuit Breaker

Communication Port

USB

0°C–40°C

Operation Temperature

0 to 95% non-condensing

Operation Relative Humidity

Storage Temperature

-15°C–50°C

Net Weight

29.3 lb

Dimensions (HxWxD)

10.8 x 3.4 x 16.1 IN

Specifications may change without prior notice.

TROUBLESHOOTING

Symptom

Possible Cause

Action to Take

Ensure the UPS is securely
connected to an AC outlet.

The UPS is not
connected to the
power source.

UPS will not turn
on

Circuit Breaker has
tripped.

Reduce the amount of equipment
plugged into the “Battery Backup &
Surge Protection” outlets of the UPS.
Reset the circuit breaker by pushing it
back in. Switch the UPS back on.

Turn off the UPS and reduce the
amount of equipment connected to
these outlets.

The “Battery Backup &
Surge Protection”
outlets are overload.

UPS is making a
continuous
sound and the
“Overload”
indicator is on

The UPS battery is
discharged due to a
power outage and has
not recharged.

Charge the battery for 8 hours. The
UPS runtime is reduced until the
battery is fully charged.

UPS does not
provide
expected
runtime

Back-UPS is heavily
loaded.

Unplug non-essential equipment
(printers, scanners, etc) from the
Battery Backup outlets and plug into
'Surge Only' outlets
Disconnect non-essential equipment
from the UPS. Reset (push in) the
circuit breaker and switch the UPS
on.

The UPS circuit
breaker “tripped”.

Plug equipment in one-at-a-time. If
the circuit breaker trips again,
disconnect the device that caused
the breaker to trip.

UPS does not
power essential
equipment
during an outage

Replace the battery or the battery
module.

The battery has
reached the end of its
life.

Unplug device from 'Surge Only'
outlet and move to a 'Battery Backup
outlet.

Equipment plugged
into a Surge Only
outlet.

Flashing
Indicators

Internal UPS fault.

Contact Technical Support (see
Service and Support below).