beautypg.com

Installation, Important: save these instructions, Specifications – Regency U37-NG NATURAL GAS User Manual

Page 5: Before you start, General safety information

background image

U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater

5

IMPORTANT:

SAVE THESE

INSTRUCTIONS

The ULTIMATE Rear Vent Direct Vent Free-
standing Gas Stove must be installed in accord-
ance with these instructions. Carefully read all
the instructions in this manual first. Consult the
building authority having jurisdiction to deter-
mine the need for a permit prior to starting the
installation.

Note: Failure to follow the instructions

could cause a malfunction of the
heater which could result in death,
serious bodily injury, and/or prop-
erty damage. Failure to follow these
instructions may also void your
fire insurance and/or warranty.

SPECIFICATIONS

Fuels:

U37-NG is approved for use with
natural gas.
U37-LP is approved for use with
liquefied petroleum gases (propane).

Electrical: 120 V A.C. system.

Circulation Fan: Variable speed, 125/75.

Log Sets: Ceramic fibre, 7 per set.

Vent System:

Axial (6-5/8" outer / 4" inner liner)
rigid flue and Riser Vent Terminal.

BEFORE YOU START

Safe installation and operation of this appliance
requires common sense, however, we are
required by the Canadian Safety Standards
and ANSI Standards to make you aware of the
following:

INSTALLATION

4) We recommend that you plan your installa-

tion on paper using exact measurements
for clearances and floor protection before
actually installing this appliance. Have a
qualified building inspector review your
plans before installation.

GENERAL SAFETY

INFORMATION

1) The appliance installation must conform

with local Canadian Electrical Code.

2) The appliance when installed, must be elec-

trically grounded in accordance with local
codes, or in the absence of local codes with
the current National Electrical Code, ANSI/
NFPA 70 or CSA C22.1 Canadian Electrical
Code.

3) The appliance should be inspected for

shipping damage before use and serviced
annually by a professional service per-
son
. More frequent cleaning may be re-
quired due to excessive lint from carpeting,
bedding material, etc. It is imperative that
control compartments, and circulating air
passageways of the appliance be kept
clean and free from excessive lint from
carpeting.

4) See general construction and assembly

instructions. The appliance and vent should
be enclosed when installed in or passing
through a living area, where children may
come in contact with it.

5) This appliance must be connected to the

specified vent and termination cap to the
outside of the building envelope. Never vent
to another room or inside a building. Make
sure that the vent is fitted as per the instruc-
tions starting on page 6.

6) Inspect the venting system annually for

blockage and any signs of deterioration.

7) Venting terminals shall not be recessed into

a wall or siding.

8) Any safety glass removed for servicing

must be replaced prior to operating the
appliance.

9) To prevent injury, do not allow anyone who

is unfamiliar with the operation to use the
fireplace.

1) Provide adequate clearances for servic-

ing, proper operation and around the air
openings into the combustion chamber.

2) The appliance must be installed on a flat,

solid, continuous surface (e.g. wood, met-
al, concrete). This may be the floor, or it can
be raised up on a platform to enhance its
visual impact. The appliance may be in-
stalled on carpeting, tile, wood flooring or
other combustible material, because the
appliance's metal pedestal base extends
the full width and depth of the appliance.
The ULTIMATE Rear Vent Direct Vent Free-
standing Gas Stove can be installed in a
wide variety of ways and will fit nearly any
room layout. It may be installed in a re-
cessed position, framed out into the room,
or across a corner.

3) The ULTIMATE Rear Vent Direct Vent Free-

standing Gas Stove is approved for manu-
factured home installations, see pages 6 to
9 for the required vent arrangements. If
installed into a manufactured home the unit
must be bolted down to the floor.

Emissions from burning wood or gas could
contain chemicals known to the State of
California to cause cancer, birth defects or
other reproductive harm.

DUE TO HIGH TEMPERATURES,
THE APPLIANCE SHOULD BE LO-
CATED OUT OF TRAFFIC AND
AWAY FROM FURNITURE AND
DRAPERIES.

WARNING: FAILURE TO INSTALL
THIS APPLIANCE CORRECTLY
WILL VOID YOUR WARRANTY AND
MAY CAUSE A SERIOUS HOUSE
FIRE.

CHILDREN AND ADULTS SHOULD
BE ALERTED TO THE HAZARDS OF
HIGH SURFACE TEMPERATURES,
ESPECIALLY THE FIREPLACE
GLASS, AND SHOULD STAY AWAY
TO AVOID BURNS OR CLOTHING
IGNITION.

YOUNG CHILDREN SHOULD BE
CAREFULLY SUPERVISED WHEN
THEY ARE IN THE SAME ROOM AS
THE APPLIANCE.

CLOTHING OR OTHER FLAMMA-
BLE MATERIAL SHOULD NOT BE
PLACED ON OR NEAR THE APPLI-
ANCE.

INSTALLATION AND REPAIRS
SHOULD BE DONE BY A QUALI-
FIED SERVICE PERSON. THIS AP-
PLIANCE SHOULD BE INSTALLED,
REPAIRED, INSPECTED BEFORE
USE AND AT LEAST ANNUALLY
BY A QUALIFIED SERVICE PER-
SON. MORE FREQUENT CLEAN-
ING MAY BE REQUIRED DUE TO
EXCESSIVE LINT FROM CARPET-
ING, ETC. IT IS IMPERATIVE THAT
THE CONTROL COMPARTMENT,
BURNERS AND CIRCULATING AIR
PASSAGEWAYS OF THE APPLI-
ANCE BE KEPT CLEAN.