beautypg.com

Warning, High altitude installations, Connecting multiple water heaters – Rinnai R94LSE User Manual

Page 29

background image

VA Series Outdoor LS Manual

29

High

Altitude

Installations

1

2

3

4

5

6

7

8

ON

F

F

O

Switch No.

1

2

3

4

5

6

7

8

ON

F

F

O

Switch No.

1

2

3

4

5

6

7

8

ON

F

F

O

Switch No.

1

2

3

4

5

6

7

8

ON

F

F

O

Switch No.

0-2000 ft

(0-610 m)

2001-5200 ft

(610-1585 m)

5201-7800 ft

(1585-2377 m)

7801-10200 ft

(2377-3109 m)

Switch No. 2

OFF

OFF

ON

ON

Switch No. 3

OFF

ON

OFF

ON

Set dip switches 2 and 3 to the values shown in table
below for your altitude. The default setting for the
appliance is 0-2000 ft (0-610 m) with switches No. 2
and No 3 in the OFF position.

Connecting Multiple Water Heaters

The EZConnect cable is an optional accessory that
connects 2 water heaters and allows them to function
as one hot water source.

The MSA-2M and MSA-2S packs are optional
accessories that connects 2 to 5 water heaters and
allows them to function as one hot water source.

Refer to the instructions that come with the accessory
for complete installation information.

Number of Connected Water Heaters:

Accessories Necessary:

2

(1) EZConnect Cable

or

(1) MSA-2M

3

(1) MSA-2M

and

(1) MSA-2S

4

(1) MSA-2M

and

(2) MSA-2S

5

(1) MSA-2M

and

(3) MSA-2S

Guidelines

Do not install both the EZConnect and the MSA
packs because they are not designed to operate
together.

Water heaters connected with the EZConnect Cable
or the MSA-2M and MSA-2S packs cannot be used
for the Bath Fill function.

Water heaters should be installed less than 18
inches apart so that the cables will reach between
units and to prevent temperature fluctuations (cold
water sandwich effect) when the water is shut off
and turned back on.

Temperature settings can only be changed on the
controller for the primary unit.

WARNING

DO NOT adjust the other dip
switches unless specifically
instructed to do so.

This manual is related to the following products: