beautypg.com

Clearances from appliance, Attachment of the water heater – Rinnai RC98I User Manual

Page 17

background image

Manual - Rinnai Condensing Water Heaters

17

Clearances

from

Appliance

1. Identify the installation location and confirm that

the installation will meet all required clearances.

2. Securely attach the water heater to the wall using

any of the holes in the wall installation brackets
which are at the top and bottom of the water
heater. Ensure that the attachment strength is
sufficient to support the weight. Refer to the
weight of the water heater in the Specifications
section.

NOTE: Rinnai water heaters should be installed in an

upright position. Do not install upside down
or on its side.

Attachment of the Water Heater

wall installation

brackets

to Combustibles

to Non-

Combustibles

Top of
Heater

6 inches *
(152 mm)

2 inches *
(51 mm)

Back of
Heater

0 (zero)

0 (zero)

Front of
Heater

6 inches
(152 mm)

6 inches
(152 mm)

Sides of
Heater

2 inches
(51 mm)

1/2 inch
(13 mm)

Ground 12

inches

(305 mm)

12 inches
(305 mm)

Vent

0 (zero)

0 (zero)

The clearance for servicing is 24 inches in front of the water heater.

For closet installation: clearance is 6 inches (152 mm) from the front.

* Zero inches from vent components and condensate drain line.

to Combustibles

to Non-

Combustibles

Top of
Heater

12 inches
(305 mm)

2 inches
(51 mm)

Back of
Heater

0 (zero)

0 (zero)

Front
(Panel)

24 inches
(610 mm)

0 (zero)

Sides of
Heater

6 inches

(152 mm)

1/8 inch

(3.2 mm)

Ground 12

inches

(305 mm)

2 inches
(51 mm)

Front
(Exhaust)

24 inches
(610 mm)

24 inches
(610 mm)

RC80i, RC98i

RC80e, RC98e

to side

to front

to top

to floor/ground