beautypg.com

3 controls and indicators, 1 powering the base unit, 2 indicators – RCA LDK 5481 User Manual

Page 38: 3 set-up items

background image

v4.0

LDK 5481 + LDK 4700 User’s Guide | Base unit

3-10

3.3

Controls and indicators

Figure 3-1. DigiLink base unit controls

3.3.1

Powering the base unit

Set the power switch to the on position (I). The power on indicator in the switch lights
when the unit is powered.

3.3.2

Indicators

Table 3-2. Ready indicator

Table 3-3. On-Air indicator

3.3.3

Set-up items

There are five items that can be accessed via the set-up buttons:

Camera number (CA)

Subcarrier adjustment (SC)

H-phase (HP)

Status (ST)

Menu Off (OF)

Ready

On-air

Mains

DigiLinK - BASE UNIT

LDK 4700

Power switch
and indicator

Set-up
buttons

On-air
indicator

Display

Ready
indicator

indication

description

off

no camera video signal detected.

green (OK)

camera video signal detected.

flashing yellow

no camera video signal detected and power failure or fan
failure.

flashing yellow/green

camera video signal detected and power failure or fan
failure.

indication

description

On

The camera is on air.

Off

The camera is not on air.

This manual is related to the following products: