11.2 Water drain connection

max.

4000 mm

min. 400 mm

max. 850 mm

Connect the water drain hose to:
• The sink spigot. Attach the water drain

hose under the kitchen counter. This
prevents that waste water from the
sink goes back to the appliance.

• A stand pipe with vent-hole. The inter-

nal diameter must be minimum 40
mm.

Remove the sink plug when the appli-
ance drains. This prevents water to go
back to the appliance.
An extension hose for the water drain
hose must be shorter than 2 m and with
the same diameter as the water drain
hose.

A

If you connect the water drain hose to a
trap spigot under the sink, remove the
plastic membrane (A). A not complete
removal of the membrane causes a
blockage in the spigot and problems
with drain.
The appliance has a non-return valve
that prevents dirty water to go back to
the appliance. If there is a non-return
valve in the sink spigot, remove it to pre-
vent the appliance to drain incorrectly.

12. TECHNICAL INFORMATION

Dimensions

Width / Height / Depth
(mm)

596 / 850 / 610

Electrical connection

Refer to the rating plate.

Voltage

220-240 V

Frequency

50 Hz

Water supply pressure

Min. / max. (bar / MPa)

(0.5 / 0.05 ) / (8 / 0.8 )

Water supply

1)

Cold water or hot water

2)

max. 60 °C

Capacity

Place settings

12

Power consumption

Left-on mode

0.10 W

Off-mode

0.10 W

1) Connect the water inlet hose to a water tap with a 3/4'' thread.
2) If the hot water comes from alternative sources of energy, (e.g. solar panels, aeolian

energy), use the hot water supply to decrease energy consumption.

ENGLISH