beautypg.com

Maintenance, Fan replacement – Regency Wraps F33 User Manual

Page 19

background image

Regency

®

F33-3 Freestanding Gas Stove

19

View from back of stove

Strain relief

grommet

WA

RN

ING

240

Vol

ts

Tur

n o

ff p

ower

befo

re o

penin

g.

Placement of Decal

“Warning 240 Volts

Turn Off Power”

Wiring Diagram

Diagram 3

FAN REPLACEMENT

For Leg Unit: Remove 7 screws, remove bottom access panel and
replace fan assembly.

1) Disconnect power to fan.

2) Open pedestal door and remove door cover plate by removing 4

screws. See diagram 1.

Diagram 1

3) Remove valve cover plate by removing 2 screws.

4) Disconnect the molex plug (from inside the stove).

Note: The #8 ground lug is a dedicated ground for mobile
home use only.

5) Loosen the four 8-32 x 1/2 screws provided into the nutserts

as shown in diagram 3. NOTE: Make sure the fan is supported
as it may fall when the 4 screws are loosened.

Diagram 2: Ground Lug

6) Disconnect the 2 ground wires (green and yellow/green striped)

to the ground lug as per diagram 2.

Note: The #8 ground lug is a dedicated ground for mobile
home use only.