beautypg.com

Maintenance, Removing valve assembly, Aeration adjustment – Regency Wraps F33 User Manual

Page 17: Pilot adjustment, Thermopile/thermocouple replacement

background image

Regency

®

F33-3 Freestanding Gas Stove

17

REMOVING VALVE ASSEMBLY

1) Shut off gas supply.

2) If optional fan is installed, disconnect power source to stove.

3) Remove access panel.
a) Front panel on pedestal model. See diagram 1.
b) Panel from bottom of leg shield. See diagram 2.

Note:

Access panel only has to be loosened to be taken out.

Diagram 1

Diagram 2

AERATION ADJUSTMENT

The burner aeration is factory set. Adjustment may be needed due to the
local gas supply or altitude. As a general rule if the fl ame is too yellow
open up the air shutter, if it is too blue close the air shutter.

NG

11

mm

LPG

wide

open

Note:

This adjustment only to be made by an authorised

person.

PILOT ADJUSTMENT

Periodically check the pilot fl ames. Correct fl ame pattern has three
strong blue fl ames: 1 fl owing around the thermopile, 1 around the
thermocouple and 1 fl owing across the burner (it does not have
to be touching the burner).

Note:

If you have an incorrect fl ame pattern, contact your

Regency

®

dealer for further instructions.

MAINTENANCE

Incorrect fl ame pattern will have small, probably yellow fl ames,
not coming into proper contact with the rear burner or thermopile
or thermocouple.

Top View of pilot fl ame

Top View of pilot fl ame

THERMOPILE/THERMOCOUPLE

REPLACEMENT

1) Loosen the thermocouple or thermopile with a 9mm spanner at

bracket.

2) Disconnect thermocouple by loosening nut from the valve with

a 9mm spanner. Disconnect thermopile by loosening 2 screws
marked TP on the valve.

3) Drop the thermocouple or thermopile down from the bracket and

pull it out of the unit.

4) Reinstall the new ones in reverse order.