Nexgrill 720-0439 User Manual
Page 13
GAS HOOK-UP
NEVER CONNECT AN UNREGULATED
GAS SUPPLY LINE TO THE APPLIANCE.
USE THE REGULATOR/HOSE ASSEMBLY
SUPPLIED WITH THIS OUTDOOR GAS
APPLIANCE.
This is a liquid propane configured grill. Do
not attempt to use a natural gas supply.
Total gas consumption (per hour) of this
stainless steel gas grill with all burners on
“IGNITE/HI”:
Main burner 30,000 Btu/hr
Side burner 12,000 Btu/hr
Sear Burner 15,000 Btu/hr
Rear burner 10,000 Btu/hr
Total
67,000 Btu/hr
L.P. TANK REQUIREMENT
A dented or rusty L.P. tank may be
hazardous and should be checked by your
L.P. supplier. Never use a cylinder with a
damaged valve. The L.P. gas cylinder must
be constructed and marked in accordance
with the specifications for L.P. gas cylinders
of the U.S. Department of Transportation
(DOT) or the National Standard of Canada,
CAN/CSA-B339, Cylinders, Spheres and
Tubes for Transportation of Dangerous
Goods; and Commission, as applicable.
Overfilling prevention device (OPD) shall be
provided on cylinder & QCCI connection on
the cylinder valve, ANSI/CGA-V-1. The
cylinder supply system must be arrange for
vapor withdrawal. Make sure tank is leveled
with bottom panel for proper vapor withdraw.
The cylinder must include a collar to protect
the cylinder valve. The cylinder must be
provided with a shut off valve terminating in
an L.P. gas supply cylinder valve outlet
specified, as applicable, for connection type
QCC1 in the standard for compressed
gas cylinder valve outlet and inlet
connection ANSI/CGA-V-1.
Manifold pressure: 11 inches water column
(W.C.).
L.P. GAS HOOK-UP
Ensure that the rubber “O” Ring on the LP
cylinder valve is in place and that the hose
does not come into contact with the grease
tray or the grill head. Set the liquid propane
gas cylinder into the slide-out tray making
sure that the cylinder is level with the
bottom panel, thus allowing proper vapor
withdrawal.
CONNECTION
Your stainless steel grill is equipped with
gas supply orifices for use only with liquid
propane gas. It is also equipped with a high
capacity hose/regulator assembly for
connection to a standard 20lb. L.P. cylinder
(18-1/4” (46.35cm) high, 12-1/4”(31cm)
diameter). To connect the L.P. gas supply
cylinder, please follow the steps below:
1. Make sure tank valve is in its full off
position (turn clockwise to stop)
2. Check tank valve to assure it has
proper external male threads (type 1
connection per ANSIZ21.81)
3. Make sure all burner valves are in their
off position.
4. Inspect valve connections, port, and
regulator assembly. Look for any
damage or debris. Remove any debris.
Inspect hose for damage. Never
attempt to use damaged or obstructed
equipment. See your local L.P. gas
dealer for repair.
9