Displaying the optimum digital mammography image, Accessories – Eizo Digital Mammography Monitor User Manual

Page 4

background image

Quality Control Sensor

Digital Mammography Monitor

Quality Control Tool

Four options are available:

Displaying the Optimum Digital Mammography Image

EIZO offers all the necessary components for correct digital mammography image display.

Bit

Compatible Operating System

Frame Buffer Memory

Bus Interface

Maximum Disply Resolutions

Output Terminals

Dot Clock

Scanning Frequency (H, V)

Maximum Power Consumption

12-bit /10-bit / 8-bit
Windows XP / 2000 Professional
128 MB
PCI 32-bit (33 MHz / 66 MHz)
2048 x 2560
DVI-I x 2
Up to 148 MHz
103.9 kHz
50 Hz
16.8 watts

High-Performance Graphics Board

Standard Configuration

10-bit / 8-bit
Windows XP / 2000 Professional
256 MB
PCI 32-bit (33 MHz) / 64-bit (66 MHz)
2048 x 2560
DVI-I x 2
Up to 148 MHz
103.9 kHz
50 Hz
40 watts

8-bit
Windows XP
1 GB
PCI Express x 16
2048 x 2560
DVI-D x 2
214.25 MHz
131 kHz
50 Hz
75 watts

8-bit
Windows XP
256 MB
PCI Express x 16 / x 1
2048 x 2560
DVI-D x 2
162 MHz
75 kHz
60 Hz
22 watts

Accessories

Monitor Cleaning Kit

Keep your screen free from dust and fingerprints with
this screen cleaner kit. Includes pump spray and cloth.
(Bundled with GS520-CLG and GS520-BLG.)

Panel Protector

Protect against scratches and dust with high light
transmission panel.

Dual Height Adjustable Stand

Mount two panels in either portrait or landscape
orientation.

5

6

PAS 1054

“ Requirements and Testing of Digital Mammography
Equipment ” established by the Normenausschusses
Radiologie (DIN NAR) in cooperation with the Deutschen
Röntgengesellschaft (DRG) and others. In line with the
QS-RL (Qualitätssicherungs-Richtlinie) quality assurance
ordinance, it is mandatory in Germany to refer to this
standard when conducting monitor quality assurance.

EIZO's easy-to-use RadiCS quality control
software performs precise calibration conforming
to DICOM Part 14 and enables quality control
complying with ACR Practice Guideline and
other QC standard for digital mammography
monitors.

Once attached to the top of the monitor the
Clip-On Swing Sensor G1 can remain in place
and is ready for use. This saves the time and

trouble of attaching
a n d r e m o v i n g i t
w h e n p e r f o r m i n g
quality control tasks.

Quality Control of Digital Mammography Monitor

As with the use of film mammography, image quality testing of
the monitor at installation and regularly during use should be
carried out. This ensures that the monitor maintains a consistent
display of quality digital mammography.

An option of

An option of clear

clear base and

base and

blue

blue base backlights are available.

base backlights are available.

Paired monitors which provides the same

Paired monitors which provides the same

color and grayscale for two monitors

color and grayscale for two monitors
bundled as a pair in one box, also available.

bundled as a pair in one box, also available.

ACR “Practice Guideline for Determinants of Image

Quality in Digital Mammography”

A guideline established by the American College of Radiology
(ACR) in cooperation with the American Association of
Physicists in Medicine (AAPM), Radiological Society of North
America (RSNA), and Society for Imaging Informatics in
Medicine (SIIM).

EUREF “European Guidelines for Quality Assurance

in Breast Cancer Screening and Diagnosis”
A s t a n d a r d i s s u e d b y t h e E u r o p e a n C o m m i s s i o n i n
cooperation with the European Reference Organization for
Quality Assured Breast Screening and Diagnostic Services
(EUREF), and European Breast Cancer Network (EBCN),
European Society of Mastology (EUSOMA).