Top or rear exit vertical termination, 90° h – Napoleon Fireplaces BGD36PTR User Manual

Page 13

background image

13

W415-0210 / E / 06.25.03

REQUIRED
VERTICAL RISE
IN FEET

V

T

HORIZONTAL VENT RUN PLUS OFFSET IN FEET

H

T

The shaded area within the lines represents acceptable
values for H

T

and V

T

.

Example 6:

V

1

= 5 ft

V

2

= 10 ft

V

T

=

V

1

+

V

2

= 5 + 10 = 15 ft

H

1

= 3 ft

H

2

= 2.5 ft

H

R

=

H

1

+

H

2

= 3 + 2.5 = 5.5 ft

H

O

= .03(three 90° elbows - 90°)

= .03(90 + 90 + 90 - 90) = 5.4 ft

H

T

=

H

R

+

H

O

= 5.5 + 5.4 = 10.9 ft

H

T

+ V

T

= 10.9 + 15 = 25.9 ft

Formula 1:

H

T

< V

T

10.9 < 15

Formula 2:

H

T

+ V

T

< 40 feet

25.9 < 40

Since both formulas are met, this vent configuration is ac-
ceptable.

when

(H

T

) < (V

T

)

Simple venting configurations

FIGURE 15

FIGURE 16

For vent configurations requiring more than zero 90° elbow
(top exit) or one 90° elbow (rear exit), the following formu-
las apply:

Formula 1: H

T

< V

T

Formula 2: H

T

+ V

T

< 40 feet

See graph to determine the required vertical rise

V

T

for the

required horizontal run

H

T

.

90°

90°

90°

H

1

H

2

V

1

V

2

TOP OR REAR EXIT VERTICAL TERMINATION