beautypg.com

Nuvo NV-E6DMS-DC User Manual

Page 25

background image

MUTE input, however, will always override other volume response values with the “XM” response.

*********************************************************************************
COMMAND:

*

ZoneSet STATUS REQUEST where xx is zone # from 1 to 12.

RESPONSE:

#

-p = 1 if at least one of the permanent
values have been overridden* by an RS232 command.
-yy = EQ level, dB, 12 to +0 (flat) to

+12 in 2 dB increments if

set by RS232, -8, -6,-4, 0,
+4, +6, +8 if set on keypad.

-q = 0 if SOURCE GROUP is ON
1 if SOURCE GROUP is OFF

-u = 0 if VOLUME RESET is ON
1 if VOLUME RESET is OFF

*override set to 1 FOR THIS ZONE only if one of commands *

, *

, or

*

are issued (see descriptions below).

Once a parameter has been SET by one of these commands, it will remain UNTIL:
a. power is cycled on the Main Unit either with the front panel power switch or by removing AC power. Upon power-up,

the system will restore keypad permanent
settings (see the User Manual for details on how to perform these settings).

b. an operator manually sets one of these parameters from a keypad. This takes the unit out of OVERRIDE state, but

other RS232-commanded settings will remain until another RS232 command overrides them, or power is cycled.

This response is also issued whenever these parameters are set from a keypad.

*********************************************************************************
COMMAND:

*

Turn zone xx ON.

RESPONSE:

Same response as for

*********************************************************************************
COMMAND:

*

Turn zone xx OFF.

RESPONSE:

Same response as for

*********************************************************************************
COMMAND:

*

Turn ALL zones OFF.

RESPONSE:

#

This RESPONSE is also issued when ALL OFF is pressed on any KEYPAD.

*********************************************************************************
COMMAND:

*

Ramp ALL zones UP at a 10 dB/second rate in 1 dB steps.

RESPONSE:

#

The ramp action will be cancelled when all zones reach MAXIMUM volume, or when an

Command is received.

Note that to stop the ramp with this command before maximum volume, one reference zone must be periodically polled with a

ZxxSETSR

ZxxORp,BASSyy,TREByy,GRPq,VRSTu

ZxxBASSyy

ZxxTREByy

ZxxGRPq

ZxxON

*ZxxCONSR

ZxxOFF

*ZxxCONSR

ALLOFF

ALLOFF

ALLV+

ALLV+

*ALLHLD

*ZxxCONSR

24

This manual is related to the following products: