Power cord safety guidelines – Nokia 730C User Manual
Page 3
E
N
G
L
I
S
H
Nokia 730C
2
The female receptacle of the cord set must meet CEE-22 requirements and will look like
Figure 1 below:
For the United States and Canada
In the United States and Canada the male plug is a NEMA5-15 style (Figure 2) UL Listed
and CSA Labelled. For units which are mounted on a desk or table, type SVT or SJT cord
sets may be used. For units which sit on the floor, only SJT type cord sets may be used. The
cord set must be selected according to the current rating for your unit. Please consult Table
A below for the selection criteria for power cords used in the United States and Canada.
Power Cord Safety Guidelines
The power cord for this unit has been packed separately and has been selected according to
the country of destination and must be used to prevent electric shock.
Use the following guidelines if it is necessary to replace the original cord set.
Caution : Use a power cable that is properly grounded. Always use the AC cords listed
below for each area :
USA ...........................UL
Canada ......................CSA
Germany ....................VDE
Switzerland ................SEV
Britain .........................BASEC/BS
Japan .........................Electric Appliance Control Act
In other areas, use AC cord which meets local safety standards.
Figure 1
Cord Type Size of Conductors In Cord
Maximum Current Rating of Unit
SJT
18AWG
10Amps
16AWG
12Amps
14AWG
12Amps
SVT
18AWG
10Amps
17AWG
12Amps
Figure 2
AC PLUG CORD PRECAUTIONS FOR THE UNITED KINGDOM
FOR YOUR SAFETY PLEASE READ THE FOLLOWING TEXT CAREFULLY.
IF THE FITTED MOULDED PLUG IS UNSUITABLE FOR THE SOCKET OUTLET THEN THE
PLUG SHOULD BE CUT OFF AND DISPOSED OF SAFELY.
THERE IS A DANGER OF SEVERE ELECTRICAL SHOCK IF THE CUT OFF PLUG IS
INSERTED INTO AN APPROPRIATE SOCKET.
If a new plug is to be fitted, please observe the wiring code as shown below.
If in any doubt, please consult a qualified electrician.
WARNING: THIS APPLIANCE MUST BE EARTHED.
IMPORTANT: The wires in this mains lead are coloured in accordance with the following code:
Green-and-Yellow:
Earth
Blue:
Neutral
Brown:
Live
If the coloured wires of the mains lead of this appliance do not correspond with the coloured
markings identifying the terminals in your plug, proceed as follows:
The wire which is coloured GREEN-AND-YELLOW must be connected to the terminal in the
plug which is marked by the letter E or by the Earth symbol
or coloured GREEN or GREEN-
AND-YELLOW.
The wire which is coloured BLUE must be connected to the terminal in the plug which is
marked with the letter N or coloured BLACK. The wire which is coloured BROWN must be
connected to the terminal in the plug which is marked with the letter L or coloured RED.