Troubleshooting
Problem
Engine will not start
SOLUTION: A
Low/Surging pressure or no water flow
SOLUTION: B,C,D,E,F,G
No chemical injection
SOLUTION: H,I,J,K
Cause Solution
A- Engine starting instructions not followed
See engine manual for starting instructions
B- Insufficient water supply
See water supply section of this manual
C- Plugged pump inlet filter
See maintenance section of this manual
D- Wrong nozzle
Make sure high pressure nozzle is being used
E- Plugged nozzle
Remove nozzle, check for blockage
F- Worn nozzle
Replace nozzle
G- Leak in pressure hose
Replace pressure hose
H- Wrong nozzle
Make sure chemical nozzle is being used
I- Back pressure from extra long pressure hose
Use standard length hose
J- Leak in chemical siphon hose
Replace hose – use hose clamps if necessary
K- Chemical strainer not submerged
Make sure strainer is completely submerged
Specifications
1577541
1577542
PSI (bar)
2600 (179)
PSI (bar)
2700 (186)
GPM (l/min)
2.5 (9.4)
GPM (l/min)
2.5 (9.4)
Max Water Temp
140
°F (60°C)
Max
Water
Temp
140
°F (60°C)
Noise Level
75 dB
Noise Level
82 dB
Dimensions
L x W x H
30.5 x 24 x 24.3
Dimensions
L x W x H
30.5 x 24 x 24.3
Weight 77
lbs
Weight 83
lbs
The manufacturer reserves the right to make improvements in design
and/or changes in specifications at any time without incurring any
obligation to install them on units previously sold.
Any Questions, Comments, Problems or Parts Orders
Call Northstar Customer Service 1-800-270-0810