IF THE CHIMNEY IS
UNLINED:

A s t a i n l e s s s t e e l
liner listed to either
S t a n d a r d U L C -
S640M, ULC-S639 in
Canada or UL-1777
in the USA: Liners
f o r N e w M a s o n r y
Chimneys, may be
u s e d t o c o n n e c t
the fireplace to the
chimney. The liner
must be continuous
from the fireplace
to the chimney cap
and be installed only
per manufacturers
i n s t r u c t i o n s .
Figure 19. In both
cases, the chimney
structure must be supported by angle iron anchored into the masonry
walls. Figures 19 & 20. The allowable masonry used in chimney
construction is 3-1/2" brick, solidly mortared and fully encasing the
fl ue. Ensure there are no leaks.

In no case is the masonry enclosure to be supported by the NZ-26
fi replace. Allow a 1" (one inch) air cavity for expansion.

Remove the nails from the shingles above and to the sides of the
chimney. Place the fl ashing over the chimney pipe and slide under-
neath the sides and upper edge of the shingles. Ensure that the chim-
ney pipe is properly centered within the fl ashing, giving a 3/4" margin
all around. Fasten to the roof on the top and sides. DO NOT NAIL
through the lower portion of the fl ashing. Make weather-tight by seal-
ing with caulking. Where possible, cover the sides and top edges of
the fl ashing with roofi ng material. Apply waterproof caulking, provided
with the fl ashing, around the chimney, 1" above the top of the fl ashing
and push the storm collar down into the caulking. Insert a rain cap
onto the top of the last chimney section.

FIGURE 18

INSTALLING FLASHING AND

STORM COLLAR

FIGURE 17

FLUE TILE SUPPORT FOR A MASONRY FIREPLACE

HI-TEMP GASKET

HI-TEMP GASKET

FIREPLACE TOP

FIREPLACE TOP

For a masonry fi replace use a fl ue tile support. For a pre-fabricated
chimney use an anchor plate.

Model NZ-26 may be connected
to either a lined or unlined
masonry chimney.

IF THE CHIMNEY IS LINED,
the flues must be made of
vitrifi ed clay and be in sizes of
8" square, 8" x 12", or 8" round
with a minimum height of 11
feet above the fireplace. 8"
round fl ues are recommended.
Installation must conform to
both national and local code
requirements.

FIGURE 19

FIGURE 20

CONNECTION TO A MASONRY

CHIMNEY

FIGURE 22

FIGURE 21

FIREPLACE TOP

FIREPLACE TOP

ANCHOR PLATE

ANCHOR PLATE

HI-TEMP GASKET

HI-TEMP GASKET

NorthlineExpress.com

http://www.northlineexpress.com