Main burner goes out;
pilot goes out.

REFER TO "MAIN BURNER GOES OUT; PILOT STAYS ON"

Thermocouple shorting or

Vent re-circulating
(MODEL GDS60 ONLY)

- check joint seals and installation.

- loosen and tighten thermocouple
- clean thermocouple and valve connection.
- replace thermocouple.
- replace valve.

Exhaust fumes
smelled in room,
headaches.

- check all seals.

Fireplace is spilling.

Carbon is being de-
posited on glass, logs
or combustion cham-
ber surfaces.

Flame is impinging on the
logs or combustion chamber.

- check that the logs are correctly positioned.
- open air shutter to increase the primary air.
- check the input rate: check the manifold pressure and orifice
size as specified by the rating plate values.
- check that the door gasketing is not broken or missing and
that the seal is tight.
- check that both vent liners are free of holes and well sealed at
all joints.
- check that minimum rise per foot has been adhered to for any
horizontal venting.

Air shutter has become
blocked

- ensure air shutter opening is free of lint or other obstruc-
tions.

Flames are very
aggressive.(GDS60
REAR VENT VERTI-
CAL TERMINATION)

Venting action is too great.

- tighten door clamps

- restrict vent exit with restrictor vent kit, GDSRP-KT.

Door is ajar

MODEL GDS60 ONLY:
Main burner flame is
a blue, lazy, transpar-
ent flame.

Blockage in vent.

- remove blockage. In really cold conditions, ice buildup may
occur on the terminal and should be removed as required.

- refer to Figure 27 to ensure correct location of storm collars.

Incorrect installation (vertical
termination only).

White / grey film forms.

Sulphur from fuel is being de-
posited on glass, logs or com-
bustion chamber surfaces.

- clean the glass with a recommended gas fireplace glass
cleaner. DO NOT CLEAN GLASS WHEN HOT.
If deposits are not cleaned off regularly, the glass may be-
come permanently marked.