14

W415-0158 / E / 02.19.04

For ease of assembly, a 7" telescop-
ing stove pipe may be installed over
the 4" vent connection of the adapter.
Add vent sections, twist locking
(clockwise) securely, to the required
height. The vent should extend, at
least, 3 feet above its point of con-
tact with the roof and, at least, 2 feet
higher than any wall, roof or build-
ing within 10 feet. (This is a guide-
line only; local venting codes should
be followed which may differ in
height and clearance requirements.)

Remove nails from the shin-
gles above and to the sides
of the chimney. Place the
flashing over the vent pipe
and slide it underneath the
sides and upper edge of the
shingles. Ensure that the
vent pipe is properly centered
within the flashing, giving a
3/4" margin all

around. Fasten to the roof on the top and sides.

DO NOT NAIL through the lower portion of the flashing. Make
weather-tight by sealing with caulking. Where possible, cover
the sides and top edges of the flashing with roofing material.

Apply waterproof caulking around the vent, 1" above the top
of the flashing and push the storm collar down into the caulk-
ing. Attach a rain cap to the top of the last vent section.

1. Install rigid black pipe, or 1/2" type L copper tubing with
a shut-off valve to the stove.

2. Seal and tighten the gas line securely to the flex connec-
tor.

DO NOT KINK FLEXIBLE CONNECTOR.

3. Check for gas leaks by brushing on a soap and water
solution. DO NOT USE OPEN FLAME.

4. Mark the appropriate boxes on the rating plate label to
indicate the model type depending on the installation (direct
vent or B-vent).
Figure 36.

For ease of accessibility, an optional remote wall switch
or millivolt thermostat may be installed in a convenient
location. Route 2 strand solid core millivolt wire from
the gas stove to the wall switch / millivolt thermostat.
The recommended maximum lead length depends on
the wire size:

WIRE SIZE

MAX. LENGTH

14gauge

100 feet

16gauge

60 feet

18gauge

40 feet

DIRECT VENT MODEL GDS60: Disconnect the existing wires
from terminals 1 and 3 (from the on/off switch) and re-
place with the leads from the wall switch/millivolt thermo-
stat.

B-VENT MODEL GS60: Disconnect the spill switch wire
from terminal 3 on the valve. Connect one lead from the
thermostat to terminal 3 on the valve and the other lead to
the wire from the spill switch.

FIGURE 34

FIGURE 35

FIGURE 33

FIGURE 32

FIGURE 36

INST

INST

INST

INST

INSTALLER:

ALLER:

ALLER:

ALLER:

ALLER: It is y

It is y

It is y

It is y

It is your r

our r

our r

our r

our responsib

esponsib

esponsib

esponsib

esponsiblity to c

lity to c

lity to c

lity to c

lity to chec

hec

hec

hec

heck of

k of

k of

k of

k offffff the a

the a

the a

the a

the appr

ppr

ppr

ppr

ppropria

opria

opria

opria

opriate bo

te bo

te bo

te bo

te box on the r

x on the r

x on the r

x on the r

x on the ra

a

a

a

ating pla

ting pla

ting pla

ting pla

ting plate accor

te accor

te accor

te accor

te according to the model,

ding to the model,

ding to the model,

ding to the model,

ding to the model,

venting and gas type of the unit.

venting and gas type of the unit.

venting and gas type of the unit.

venting and gas type of the unit.

venting and gas type of the unit.

GAS INSTALLATION

ADDING VENT SECTIONS

INSTALLING FLASHING

AND STORM COLLAR

This manual is related to the following products: