Napoleon Fireplaces NZ26 User Manual
Page 8
![background image](/manuals/192998/8/background.png)
W415-0156 / B / 10.31.05
8
FIGURE 11 - 4 ELBOWS
FIGURE 10 - 2 ELBOWS
FIGURE 9 - STRAIGHT UP
No Off-Set. Minimum overall chim-
ney height is 11 feet.
Single off-set with two 15°, 30° or
45° elbows. Minimum overall
chimney height is 11 feet.
Double off-set with four 15°, 30° or
45° elbows. Minimum overall chim-
ney height is 11 feet.
Installation of all types of factory-built chimney systems is to be in accordance with the chimney manufacturers
installation instructions. An appropriate chimney manufacturers anchor base plate and anchor base plate gasket is
required in order to initiate the twist lock mechanism. Use the high temperature gasket, supplied, to seal between the
anchor plate and the fireplace top.
*
*
* The first flue offset closest to the top of the
unit must be a minimum distance of 12 inches
from the top of the fireplace.
NOTE: 30° or 45° offsets may be installed back to back.
This fireplace was tested to CAN/ULC S610 Standard for Factory Built Fireplaces, and to UL 127 Factory Built Fire-
places. This Factory Built Fireplace is certified to burn Fire Wood. The Factory Built Fireplace model: NZ26 has met
test criteria for Zero Clearance Installation to Combustible Surfaces.
Any 6" diameter chimney listed to these standards may be installed. In accordance with these standards, the unit may
also be connected to any chimney listed to ULC-S629 or UL-103HT.