beautypg.com

Technical tips on the ls-4500af, 44 nikon, Film scanner ls-4500af user's manual – Nikon LS-4500AF User Manual

Page 64

background image

44

Nikon

Film Scanner LS-4500AF User's Manual

0

4096

256

Input

Output

0

4096

256

Input

Output

White is being skipped

Black is being lost

CCD signal

black

A change of gradient means a change of gain. When a gamma value with
twice the gradient is set for only half of the input, 256-step output will be
obtained.

However, note that setting a gamma value with a sharp gradient toward the
black side means amplifying the noise element.

In addition to an auto-LUT function, the LS-4500AF has an LUT function
set by users, enabling downloading from an outside source.

0

4096

256

Input

Output

9. Technical Tips on the LS-4500AF