beautypg.com

Gpib-100a specifications, Table 1-1. system configuration characteristics, Tables – National Instruments GPIB-100A User Manual

Page 12

background image

Chapter 1

Description of the GPIB-100A

© National Instruments Corporation

1-3

GPIB-100A User Manual

GPIB-100A Specifications

The following tables show the system configuration; the performance, operating, electrical,
environmental, and physical characteristics of the GPIB-100A, as well as providing a list of
available GPIB-100A components and accessories.

Table 1-1. System Configuration Characteristics

Characteristic

Specification

distance per extension

up to 300 m

loading per extension

up to 14 additional devices

multiple extensions

permitted in any combination of star or linear pattern

GPIB driver output

no restrictions (automatic conversion to 2

µ

sec

circuit and T1 timing

T1 delay on remote side is built in)

of source device

Note:

T1 is the data settling time (DIO valid to DAV) and varies according to the type of
drivers and the system configuration used.