Technical data – Nortec GS Series User Manual
Page 7
SPECIFICaTION
GS 100
GS 200
GS 300
GS 400
GS 500
GS 600
Capacity: lbs/hr
25-105
25-210
25-315
25-420
25-525
25-630
Capacity: kg/hr
11-47
11-95
11-143
11-191
11-238
11-286
Input BTU/hr max
140,000
280,000
420,000
560,000
700,000
840,000
Input kJ/hr max
41
82
124
165
206
247
Flue Emissions
Low CO (<10ppm) and NOx (<40ppm)
Unit rated Amps
4
6
8
10
12
14
Voltage/Phase
120V/1
120V/1
120V/1
120V/1
120V/1
120V/1
Unit rated Amps
2
3
4
5
6
7
Voltage/Phase
208-240/1
208-240/1
208-240/1
208-240/1
208-240/1
208-240/1
technical data
INSTaLLaTION FEaTuRES & REquIREMENTS
Single point cabinet door fastening for easy removal.
Choice of venting comes standard allowing greater installation flexibility,
B or BH venting.
Cabinet and insulation allows mounting to combustible surfaces for
minimum space requirement.
Exclusive full size cleanout port for fast and easy servicing.
Floor stand optional for GS indoor units.
All service connections exterior to the humidifier ready for field
connections.
120, 208-240V single phase power supply.
Steam outlet configuration ready for duct distributor, remote mounted
blower pack or Short absorption manifold connection.
7