Tda8752b, Philips semiconductors – NXP Semiconductors Triple high-speed Analog-to-Digital Converter 110 Msps TDA8752B User Manual
Page 26

Philips Semiconductors
TDA8752B
Triple high-speed Analog-to-Digital Converter 110 Msps
Product specification
Rev. 03 — 21 July 2000
26 of 38
9397 750 07338
© Philips Electronics N.V. 2000. All rights reserved.
G
E(rms)
channel-to-channel gain
matching (RMS value)
maximum coarse gain;
T
amb
= 25
°
C
−
1
−
%
minimum coarse gain;
T
amb
= 25
°
C
−
2
−
%
Clamps
P
CLP
precision
black level noise on RGB
channels = 10 mV (max.)
(RMS value); T
amb
= 25
°
C
−
1
−
+1
LSB
t
COR1
clamp correction time to
within
±
10 mV
±
100 mV black level input
variation; clamp
capacitor = 4.7 nF
−
−
300
ns
t
COR2
clamp correction time to
less than 1 LSB
±
100 mV black level input
variation; clamp
capacitor = 4.7 nF
−
−
10
lines
t
W(CLP)
clamp pulse width
500
−
2000
ns
CLP
E
channel-to-channel clamp
matching
−
1
−
+1
LSB
A
off
code clamp reference
clamp register input code = 0
−
−
63.5
−
LSB
clamp register input
code = 255
−
+64
−
LSB
clamp register input
code = 367
−
+120
−
LSB
clamp register input
code = 398
−
+136
−
LSB
Phase-locked loop
j
PLL(rms)
maximum PLL phase jitter
(RMS value)
f
clk
= 110 MHz; see
−
112
−
ps
DR
divider ratio
100
−
4095
f
ref
reference clock frequency
range
15
−
280
kHz
f
PLL
output clock frequency
range
12
−
110
MHz
t
COAST(max)
maximum coast mode time
−
−
40
lines
t
recap
PLL recapture time
when coast mode is aborted
−
3
−
lines
t
cap
PLL capture time
in start-up conditions
−
−
5
ms
Φ
step
phase shift step
T
amb
= 25
°
C
−
11.25
−
deg
ADCs
f
s
maximum sampling
frequency
110
−
−
MHz
INL
DC integral non-linearity
from IC analog input to digital
output; ramp input;
f
clk
= 110 MHz
−
±
0.5
±
1.5
LSB
Table 17: Characteristics
…continued
V
CCA
= V
11
(or V
19
, V
27
or V
99
) referenced to AGND (V
13
, V
21
, V
29
or V
96
) = 4.75 to 5.25 V; V
CCD
= V
95
referenced to DGND
(V
86
) = 4.75 to 5.25 V; V
DDD
= V
40
referenced to V
SSD
(V
41
) = 4.75 to 5.25 V; V
CCO
= V
59
(or V
69
, V
79
or V
85
) referenced to
OGND (V
48
, V
60
, V
70
or V
82
) = 4.75 to 5.25 V; AGND, DGND, OGND and V
SSD
connected together; T
amb
= 0 to 70
°
C; typical
values measured at V
CCA
= V
DDD
= V
CCD
= V
CCO
= 5 V and T
amb
= 25
°
C; unless otherwise specified.
Symbol
Parameter
Conditions
Min
Typ
Max
Unit