1)

Options / model variants

POSEIDON 5

CHEM

MAX

CHEM

MAX

ca.

5%

3%

1%

0%

4.3 Pressure regulation

(Tornado Lance)

1. Turn the twist grip on the

spray unit:

High pressure =

clockwise (+)

Low pressure =

anticlockwise (–)

4.4 Pressure regulation

with the FlexoPowerJet
nozzle

1. Twist cap of the FlexoPowerJet

nozzle:

High pressure = MAX.

Low pressure = MIN.(CHEM)

4.5 Pressure regulation on

the machine

1. Set pressure and water vol-

ume by twisting the pres-
sure/volume regulation knob
on the machine.

4.6 Using cleaning agents

Cleaning agent can be drawn
in via the injector installed as
standard only in low-pressure
mode:

1. Dilute cleaning agent ac-

cording to the manufacturer‘s
instructions. Capacity see
chapter 9.4 Technical Data.

2. Tornado lance

1)

:

Set pressure regulation on
spray lance to low pressure
(–), or
FlexoPowerJet nozzle

1)

:

Turn cap of the FlexoPower-
Jet nozzle towards „CHEM“
up to the stop.

3. The intaken volume of clean-

ing agent can be regulated by
turning the metering valve.

4. Main switch

Turn the switch to position
I „.

5. Operate the spray gun.

CAUTION!
Never allow cleaning agent
to dry on the surface to be
cleaned. The surface may be
damaged.