beautypg.com

Preparing floor opening(s), Installing duct connector – Nordyne E3 Series User Manual

Page 11

background image

11

Preparing Floor Opening(s)

1. Mark fl oor opening(s) as shown in Figure

6. Provide minimum clearances at rear
and right side walls of closet or alcove for
installation of furnace and wiring.

2. Cut

fl oor opening on outside edge of marked

line so that opening is slightly larger than
area marked.

3. Additional provisions may be necessary

for optional air conditioning or heat pump
if refrigerant lines are installed elsewhere
than at the front of the furnace.

4.

The refrigerant and entrance supply opening
dimensions may be adjusted ± 1/2”.

Installing Duct Connector

NOTE: The duct connector is designed for use
on ducts down to 12” wide. On typical ducts,
the fi nger tab duct connector may be installed
using Method B. On narrow ducts, there may be
insuffi cient clearance to bend the tabs on two
sides of the fi nger tab duct connector. In such

cases, use Method C or D. For screw down duct
connector use method E. For Platinum models
always use method A.

Method A - Platinum Series
NOTE: Flex duct used must have a minimum

temperature rating of 200

°

F and meet all

other applicable codes and standards.

1. Place duct connector through opening in

fl oor. See Figure 9.

2. Connect 14” supply duct.

2-3/8" MIN
(60 mm)

"

6-1/4

23-3/4"

(603 mm)

20"

3/4"

"

10

14-1/2"

(368 mm)

3" (76 mm)

"

4-1/4

"

5

"

3-3/8

REAR WALL OF ENCLOSURE

Furnace Outer
Door

Optional Supply Wire

Entrance

Optional

Refrigerant

Line

(Not required

for Platinum)

Center Line

17"

(432 mm)

14-1/2"

(368 mm)

16-5/8"

(422 mm)

(254 mm)

(86 mm)

(127 mm)

(108 mm)

(159 mm)

(19 mm)

(508 mm)

3-3/4"

(95 mm)

Furnace
Outline

A/C Or HP

Figure 6. Downfl ow Floor Cutout Locations (nominal dimensions)

Table 4. Floor Cavity Sizes

If "X"

fl oor cavity is:

Use Duct Connector

Model Part Number

English

Metric

(mm)

Finger

Tab

Screw

Down

7/8"

22

901987

904008

2"

51

901988

904009

4 1/4"

108

901989

904010

6 1/4"

159

901990

904011

8 1/4"

210

901991

904012

10 1/4"

260

901992

904013

12 1/4"

311

901993

904014

This manual is related to the following products: