Wiring an isolated output to an external load, Wiring an isolated output to an external load -12, Re 4-6 s – National Instruments NI 1450 Series User Manual
Page 57: Re 4-5
Chapter 4
Digital I/O Functionality
NI 1450 Series Compact Vision System User Manual
4-12
ni.com
Figure 4-5. Example of Connecting an Isolated Input to a Sourcing Output Device
Wiring an Isolated Output to an External Load
The digital output circuit sources current to external loads, as shown in
the example in Figure 4-6. The maximum output current of this circuit
is 100 mA.
Figure 4-6. Example of Connecting an Isolated Output to an External Load
Vcc
Sourcing
Output
Device
Viso
Current
Limiter
Ciso
NI 1450
Input
Digital Output
Viso
Ciso
Vcc
NI 1450
Load