Figure 8. temperature/humidity relationship, Shock and vibration, Random vibration – National Instruments Portable Monitor Accessory NI PMA-1115 User Manual
Page 10
NI PMA-1115 User Guide and Specifications
10
ni.com
Figure 8. Temperature/Humidity Relationship
Shock and Vibration
Operational shock ...................................10 g peak, half-sine, 11 ms pulse
(Tested in accordance with
IEC-60068-2-27.)
Random Vibration
Operating ................................................5 to 500 Hz, 0.31 g
rms
Nonoperating ..........................................5 to 500 Hz, 2.46 g
rms
(Tested in accordance with
IEC-60068-2-64. Nonoperating
test profile exceeds the
requirements of
MIL-PRF-28800F, Class 3.)
Rel
a
tiv
e
Humidity (%)
100
90
80
60
40
20
10
-20
0
10
20
30
40
50
60
Operation Range
Storage
Range
Storage
Range
Temperature (°C)
Twb = 39 °C
T = 40 °C,
H = 90%
T = 50 °C,
H = 55%
T = 60 °C,
H = 39%