12

Specifications

N8580-31 500 VA

Acceptable input voltage

0 - 160 VAC

Output voltage

90 - 110 VAC

Input Protection

Resettable circuit breaker

Frequency limits (on-line operation)

50 or 60 Hz, +2%, -4%

Transfer time

2 ms (normal) 4 ms (maximum)

Maximum load

500 VA / 320 W

On-battery output voltage

100 VAC

On-battery frequency

50 or 60,

±

0.1 Hz; unless synchronized to utility during brownout.

On-battery waveshape

Low-distortion sine wave

Protection

Overcurrent and short-circuit protected, latching shutdown on overload.

Noise Filter

Normal and common mode EMI/RFI suppression, 100 kHz to 10 MHz

Battery type

Spill proof, maintenance free, sealed lead-acid

Typical battery life

life varies; typical 2 years, depending on number of discharge cycles and ambient

temperature

Typical recharge time

2 to 5 hours from total discharge

Operating temperature

0 to +40 ºC (+32 to +104 ºF)

Storage temperature

-15 to +45 ºC (+5 to +113 ºF)

Operating and storage relative humidity

5 to 95%, non-condensing

Operating elevation

0 to +3,000 m (0 to +10,000 ft)

Storage elevation

0 to +15,000 m (0 to +50,000 ft)

Electromagnetic immunity

IEC 801-2 level IV, 801-3 level III, 801-4 level IV

Audible noise in dBA at 1 m (3 ft)

< 45

Size (H x W x D)

15.8 x 13.7 x 35.8 cm.

(6.2 x 5.4 x 14.1 in.)

Weight - net (shipping)

11.6 (12.9) kg.

25.5 (28.5) lb.

Safety approvals

Listed to UL 1778

EMC verification

VCCI Class 2

© NEC Corporation 1998
990-5021, Revision 1, 12/98
N8580-31