Durability, resistance, reliability - all validated by testing

* Refer to the installation environment requirements for information on the evaluation
parameters for each test.



Impact test

While turned on, the device is subjected
to half sine wave impacts at a peak value
of 147 m/s2 (15G) and a cycle of 11 ms.
While turned off, the device is subjected to
half sine wave impacts with a peak value
of 490 m/s2 (50G) and a cycle of 11 ms.

Dust resistance test (IP54 compliant)

While turned on, the device is left for 8 hours
inside a machine decompressed to 2KPa
in which talcum powder was circulating

Splash resistance test (IP54 compliant) While turned off, water is sprayed onto the

device from all directions for 5 minutes at a rate of 10ℓmin.