beautypg.com

N-Tron 400 User Manual

Page 8

background image

Rev 102507

8

DIN-Rail Mounting

Install the unit in a standard DIN-Rail. Recess the unit to allow at least 5” of horizontal clearance for fiber optic
cable bend radius (2” for TX models). Note: This unit may be mounted horizontally or vertically.

To install the unit to 35mm industrial DIN-Rail - Place the top edge of the included mounting bracket on the
back of the unit against the top flange of the DIN-Rail at a 15° angle. Rotate the bottom of the unit to the
back (away from you) until it snaps into place.


To remove the unit from the 35mm industrial DIN-Rail apply downward force to the unit until it disengages
from the bottom of the unit from the DIN-Rail. Then, rotate the unit approximately 15° upward and towards
you to completely remove the unit.


Optional Mounting

With the exception of the 524TX and 526FX2, all N-Tron™ products are designed to be mounted on
industry standard 35mm DIN-Rail. However, DIN-Rail mounting may not be suitable for all applications.
We offer two alternative mounting solutions.

Our 900 Panel Mount Assembly (P/N: 900-PM) may be used to securely mount our 100, 200, 300, 400,
500, or 900 Series products to a panel or other flat surface.

Our Rack Mount Assembly (P/N: 900-RM) may be used to mount our products to standard 19" racks.