Obd request supported pids.vi, Obd request supported pids.vi -135 – National Instruments CAN 372139B-01 User Manual
Page 161

Chapter 5
Automotive Diagnostic Command Set API for LabVIEW
© National Instruments Corporation
5-135
Automotive Diagnostic Command Set User Manual
OBD Request Supported PIDs.vi
Purpose
Executes the OBD Request Current Powertrain Diagnostic Data service to retrieve the valid 
PID values for this service.
Format
Input
diag ref in specifies the diagnostic session handle, obtained from
and wired through subsequent diagnostic VIs. Normally, it is
not necessary to manually manipulate the elements of this cluster.
error in is a cluster that describes error conditions occurring before the VI 
executes. If an error has already occurred, the VI returns the value of the 
error in cluster to error out.
status is TRUE if an error occurred. This VI is not executed when 
status is TRUE.
code is the error code number identifying an error. A value of 0 
means success. A negative value means error: the VI did not 
execute the intended operation. A positive value means warning: 
the VI executed intended operation, but an informational warning 
is returned. For a description of the code, wire the error cluster to 
a LabVIEW error-handling VI, such as the Simple Error 
Handler.
source identifies the VI where the error occurred.
Output
diag ref out is a copy of diag ref in. You can wire it to subsequent 
diagnostic VIs.
PIDs out returns an array of valid PIDs for the OBD Request Current 
Powertrain Diagnostic Data service.