Newcon Optik LRB 7x50 User Manual
Page 8
2 . R a n g e F i n d e r
Type
Measuring Range, m
Accuracy, m
Resolution, m
Measurement time, sec
Meters/Yards display
Last 10 readings recall
Reticule shape ( + or □)
Target quality indicator
Scan Mode
Speed Finder
Class 1 eye safe, 905nm
20-1,500
±1 ± 0.1%
1
<1
Yes
Yes
Optional
Optional
Yes
Optional
3. M i s c e l l a n e o u s
Battery
Battery capacity
'Low Battery' Indicator
Covering
Construction
Tripod thread
Operational Temperature
Range
Storage Temperature Range
Shock, g
Vibration, Hz
Dimensions, mm
Weight, kg
Standard 9v
>3000
Yes
Rubberized
Water resistant
1/4"x20
-25 / +50
o
C (-13 / +122
o
F)
-45 / +85
o
C (-49 / 185
o
F)
65
5 – 500
210x150x80
1.300
8
CL - clear data function: upon pressing the Action button (6)
(fig. 1) the entire data on all previous measurements will be
erased.
NOTE: After changing a battery the recall stack should be
cleared by exercising the CL mode.
OVER 100 – allows to ignore targets closer than 100m. Useful
when looking through bush.
Please note: this is an optional feature on early designs. Latest
version includes automatic “Last Target” selection that renders
obsolete the requirement for a separate manual mode selection.
c. Reflection
Distance measuring procedure includes instant statistical
processing of the package of single measuring sessions.
Qualitative result of the statistical processing is presented on the
Display as a message TARGET REFLECTION (5).
There are four statistical qualifications of the reflected signal:
• NO TARGET REFLECTION – when a steady
reflected signal isn’t received. Numerical display shows
four dashes at the distance displaying area;
• TARGET REFLECTION LOW – when the number of
steady received reflected signals is just enough to make
acceptable conclusion about the measured distance;
13