14
TROUBLESHOOTING (
CONTINUED)
IR TEST LED OFF:
Optical Interference
IR TEST LED ON OR FLICKERING:
Electromagnetic Interference
EMI (ELECTROMAGNETIC INTERFERENCE)
Identify the source of the interference. The most common sources of electromagnetic interference 
are listed in the Installation Considerations section on page 3. To eliminate EMI try the following 
methods:
 1. Move the sensor or the sensor cable away from the EMI source or move the source of the 
 EMI away from the sensor or the cable. 
 2. Connect the Sensor’s GND terminal to true earth ground (if this isn’t feasible use the main 
 system unit’s GND terminal).There are many methods for reducing interference. Which 
 solution is best for you depends on your situation. If you require further assistance call Niles 
 Technical Support at 305-238-4373 or 1-800-289-4434 (M-F 8:00 AM - 7:00PM ET). You 
 can also email Niles Technical Support at [email protected].