Experience Strength™ C-Line Owner’s Manual: Weekly Inspection
12
Clean and Lubricate Guide Rods
Inspect the exposed areas of the guide rods for cleanliness. Using a dry cloth, 
wipe any buildup of dirt or grease from the rods.
Note: On the Experience Line of strength equipment, the upper rear shroud 
must be removed to access the guide rods for inspection, cleaning, and 
lubricating (refer to 
Shroud Removal
).
Lubricate the exposed areas of the guide rods by applying a light coat of 
silicone spray lubricant. Spray the lubricant on a cloth, then wipe the guide 
rods with the cloth. 
Be careful with any lubricant spray; it can stain carpet
and clothing.
CAUTION: Do not attempt to lubricate the guide rods when the equipment is 
in use. Attempting to lubricate between the weight plates without completely 
disassembling the stack will result in serious injury.
Important: Do not use petroleum-based lubricants. These lubricants tend to 
cause a rapid buildup of dirt and hair on the weight plates, which can cause the 
plates to stick together.
Inspect Cables, Connections, and Tension
Each week, give the cables and connections a thorough inspection and check 
cable tensions. The following lists the specific things you need to inspect:
• Check the cable termination at the weight stack. For most equipment, the
exposed shank can be no more than 1¼ inches (32mm); this distance 
allows for a minimum of 10 turns of the bolt into the selector stem (refer to 
Inspect Cables and End Connections
, earlier). Check and adjust the
distance accordingly.
Also make sure that the locking jam nut is tight
against the selector stem
.
• Check the cable, especially near all pulley wheels and cams.
• Check the cable as it terminates at the cam, which is stationary on most
equipment. Inspect the bolt passing through the cam end fitting to be sure 
the two jam nuts are tightened against each other. Also, check the entire 
cable routing to verify that there is no interference with any structure. 
• Inspect the ball end of the cable where the cable connection rests in the
clevis housing.
• Make sure that each cable is properly adjusted and tightened at the top of
the weight stack.
• Check cable pulleys, end connections, and end fittings. Make sure all
connections are tight, adjusting cable tension as necessary.