4. OPERATION OF THE TESTBOARD
If not already done please follow the basic setting up instructions as in
Check if the jumper plugs are set as indicated in Figure 2. The functions of the jumpers
are as follows:
jumper
ame
function
to set as in Figure 2
A
Vcc for position A
do not care
B
Vcc for module at position B*
do not care
C
Vcc for module at position C*
yes
D
Vcc for module at position D*
do not care
JP2
5Vdc feed to Slots A, B, C, D**
no
JP3
Vcc setting 2.1-2.7-3.4V;
see Table 2
no for
Vcc=2.7Vdc default
JP4
Vcc setting 2.1-2.7-3.4V;
see Table 2
yes for
Vcc=2.7Vdc default
JP7
Vcc regulator output feed
to A, B, C, D
yes
(Table 1)
* Position C is used as an example, position B or D could be used as well.
An amperemeter for measuring module current can be inserted instead of the jumper
** +5Vdc supply (independent on JP3 and JP4 settings) option is provided for application
demos. The +5Vdc supply is NOT used on PAN4570 carrierboard.
Check if the port switches S1 near to the COM2 connector for RS232 are all set to off
position except the selected UART as noted in Figure 2/Table 3.
5. POWER SUPPLY
5.1. D.C. POWER FROM A POWER SUPPLY
Set the power switch SW7 to the position 2 = off.
Connect a power supply with 7-9VDC to one of the power inputs (P1 or P2).
In case of P1 use a plug with 5,5mm diameter and the positive terminal at the centre
contact.