beautypg.com

Testing for ieee802.15.4 parameters – Panasonic PAN4570 User Manual

Page 15

background image

CLASSIFICATION
Einstufung

No.
DS-Eval4570-2400

REV.

C

SUBJECT
Thema

EvalBoard PAN4570

PAGE
Seite

15 of 20

CUSTOMER’S CODE
EvalPAN4570

PANASONIC’S CODE

DATE
Datum

06.11.2006

European Technology Center

Panasonic Electronic Devices (EUROPE) GmbH

APPROVED

genehmigt

CHECKED

geprüft

DESIGNED

Erstellt

For more information on the items above see the website of Ember

TM

Inc.

(www.ember.com)

and the documentation included in the Ember

TM

Insight Desktop

package as part of the Ember

TM

development kits.

9.4. TESTING FOR IEEE802.15.4 PARAMETERS

The software on PAN4570 as delivered is the >Ember

TM

Range Test Application 2.0<

(Version 1. Oct. 2006) utility. It allows the basic RF transceiver testing including range
testing.
The basic operation of Ember

TM

Range Test Application is as follows. Typing HELP and

>return< on the terminal will display a complete list of commands, below the mostly used
commands are explained.

e

exit, leaving the last funktion

channel x

channel entry, where

x=b sets the lowest channel at 2405MHz

x=12 sets a channel at 2440MHz

x=1a sets the highest channel at 2480MHz

txtone

turns on an unmodulated carrier

txstream

turns on a continuously modulated carrier

transmit x

transmission of packets according to IEEE802.15.4

receive

reception of packets (requires another device set to transmit on the same
channel)
remark: for resetting the packet error counter to zero the transmitter has to
be restarted

txpow

after RESET the maximum default Tx power of +3dBm is set.

with

Txpowermode 1 0

the BOOST MODE with Tx higher output power and higher

Rx sensitivity is enabled. BOOST MODE is only allowed

for PAN4570 versions with pad or U.FL RF terminal.

Hardware

RESET

or

Txpowermode 0 0 returns the module

to NORMAL MODE


All available commands are shown after typing HELP >return<., or as document on the
CD.