beautypg.com

4connect control lines – Pelco CM6700 User Manual

Page 11

background image

Pelco Manual C523M-H (6/05)

11

4

CONNECT CONTROL LINES

1.

Connect camera control lines to receivers. If your video sources are all controlled by
Coaxitron, skip this section and go to step

5

. If any of your video sources are using D

or P protocol via RS-422 communications circuits, they will connect at COM 1 on the
back of the SCU, as outlined below.

2.

Refer to Figure 10. Connect control lines to COM 1 at the connector on the back of the
SCU.

NOTE:

If D or P protocol

receivers are used, they must
all be the same protocol. D
and P protocol receivers
cannot be mixed on the
SCU’s communication port.
Coaxitron control may be
used for some of your
sources when either D or P
protocol receivers are used.

Figure 10. COM 1 Connections on the SCU

TO RECEIVERS

12-PIN PLUG-IN

CONNECTOR

COM 1 (1-6)

COM 2 (7-12)

NOTE: TO PROPERLY
SHIELD DATA CABLE
CONNECT GROUND
ON ONE END ONLY

CONNECT PINS 5 & 6 ONLY IF
USING BI-DIRECTIONAL CONTROL

VIDEO INPUTS

1

3

5

7

9

1

13

15

2

4

6

8

10

12

14

16

VIDEO OUTPUTS

1

2

3

4

LOCAL

KEYBOARD

COM 1 (1-6)

RS-422

PIN ASSIGNMENTS

PIN

FUNCTION

1

T+

2

T–

3 (OPTIONAL) GND

4

NC

5

R–

6

R+

00052

3.

Connect wiring to all receivers.

a.

Daisy-chaining (going from one receiver to another) is recommended (refer to
Figure 11) but not always possible.

NOTE:

Unless you have

receivers that are equipped
for bi-directional control, you
will only need to run two
wires (TX+ and TX-) to each
receiver.

Figure 11. Daisy-Chaining Receivers

VIDEO INPUTS

1

3

5

7

9

1

13

15

2

4

6

8

10

12

14

16

VIDEO OUTPUTS

1

2

3

4

LOCAL

KEYBOARD

00050

TO SCU

12-PIN PLUG-IN

CONNECTOR

COM 1 (1-6)

COM 2 (7-12)

NOTE: TO PROPERLY
SHIELD DATA CABLE
CONNECT GROUND
ON ONE END ONLY

CONNECT PINS 5 & 6 ONLY
FOR BI-DIRECTIONAL CONTROL

DAISY-CHAINING

RECEIVER 2

RECEIVER 1

RX-

RX-

RX+

RX+

TO ADDITIONAL