Printer Configuration
Baud Rate
Baud Rate
57600
Possible Values: 9600, 19200, 38400, 57600*
This feature sets the baud rate for the Serial interface. The value must match the setting used on the host
system.
Data Bits
Data Bits
8
Possible Values: 7, 8*
This feature sets the number of data bits in the serial character frame. The value must match the setting used on
the host system.
Stop Bits
Stop Bits
1
Possible Values: 1*, 2
This feature sets the number of stop bits included in the serial character frame. The value must match the
setting used on the host system.
Parity
Parity
None
Possible Values: None*, Even, Odd
This feature sets the parity checking requirements for the data bits in the serial character frame. The value must
match the setting used on the host system.
XON/XOFF Handshaking
XON/XOFF
Off
Possible Values: Off*, On
This feature enables or disables the XON/XOFF (DC1/DC3) character handshaking method used to control data
flow from the host system to the printer. When enabled, an XOFF character will be sent by the printer
whenever the printer’s input buffer is nearly full. An XON character will be sent whenever the printer’s input
buffer becomes nearly empty or if the control panel Setup Mode has been exited.