Prechecks before service call, Placing a service call, User manual – Plasmon MOD 910 User Manual
Page 19

Prechecks before Service Call
1.
Disk cannot be inserted.
?
Is power on?
?
Is the disk orientated correctly?
?
Is the disk the correct type?
2.
Access Failure
?
Is the cartridge inserted?
?
Is the SCSI ID set correctly?
?
Are the SCSI bus terminated correctly?
?
Is the cartridge set to write protect?
?
Are other devices on the SCSI bus operating normally?
?
Is the software device driver installed correctly?
Placing a service call
Contact your supplier or service company. They will probably require
the following information;
Where purchased
Date of Purchase
Serial Number
Description of failure
System information which may include;
?
Computer type and SCSI adapter type
?
Software configuration (in DOS this will be the CONFIG.SYS
and AUTOEXEC.BAT file)
?
Type of device driver being used
Software and Driver Updates
Do you have the latest revisions?
Contact your supplier for firmware or driver updates.
10
97705183 A
User Manual