Bc d, Fg g – Pentair Pool and SPA Heater PowerMax User Manual
Page 32
![background image](/manuals/187052/32/background.png)
P/N 471048
Rev. G 1-22-04
32
A-6
(DIAGRAM 2)
POWERMAX VENTING GUIDELINES
OUTDOOR INSTALLATION
STACK DIA.
3"
POWERMAX OUTDOOR STACK KITS
4"
4"
4"
4"
3"
KIT MODEL
471396
471396
471396
471396
471395
471395
PMX 400
PMX 350
PMX 300
PMX 250
MODEL
PMX 150
PMX 200
B
C
D
Optional Hor
iz
ontal
V
enting.
Must be the same diameter
as the v
ent connector
.
Must be suitab
le f
or use with Categor
y III
Appliances which ha
v
e
flue gas temper
atures
of less than 400 deg.
F
.
The V
ent
Pipe:
Must be not less than 7 ft.
abo
v
e
pub
lic w
alkw
a
y
s
.
Must be at least 3 ft.
abo
v
e
an
y f
orced
air inlet located within a 10 ft.
r
adius
.
A
B
C
D
E
V
ent T
ermination:
Chec
k local b
uilding codes
for setbac
k requirements
.
Proper
ty Line
4'
1'
4'
4'
W
alkw
a
y
3'
A
Must be located the f
ollo
wing distances a
w
a
y
from an
y door
, windo
w
, or g
ra
vity air inlet:
4 ft.
belo
w
, or
4 ft.
hor
iz
ontally
, or
1 ft.
abo
v
e
E
Outdoor
Stac
k Kit
6 in.
min.
F
G
G
F