beautypg.com

Installations and connections, Caution on installation, Warning – Panasonic BM-ET500 User Manual

Page 11

background image

11

INSTALLATIONS AND CONNECTIONS

WARNING

The installation described in these figures should be made
by qualified service personnel or trained system installers.

Cautions:

• This system must be installed within the protected

promise in accordance with the National Electrical
Code (NFPA70), and the local authorities having juris-
diction.

• Attach this unit to a flat wall with the supplied mounting

bracket. After the installation, secure the unit to prevent
dropping.

Caution on Installation

Secure the unit with the supplied mounting bracket to pre-
vent vibration, dropping and injury.

Notes:

• Keep the unit:

in the temperature between 0 °C and 40 °C {between
32 °F and 104 °F} and the humidity between 30 % and 80 %.

430 mm {17 in.}

21

1 mm {18 in.}

1 380 mm {54 in.} or more

(recommended)

80 mm {3 in.}

Top View

Side View

400 mm {16 in.}

900 mm {35 in.}

1 300 mm {51 in.}

400 mm {16 in.}

900 mm {35 in.}

400 mm {16 in.}

400 mm {16 in.}

700 mm {28 in.}

700 mm {28 in.}

Floor

1 300 mm {51 in.}

Keep this area free
from obstructions

Keep this area free
from obstructions

Coaxial cable (BNC)

Coaxial cable (BNC)

Camera power cable

General-purpose

power supply *

(24 V DC)

BM-ET500

(For recognition)

Camera 1

Camera 2

System Instruction (Maximum System)

OK

NG

BM-ET500

(For recognition)

In the case of Wiegand / RS-485 use

OK

NG

OK

NG

(For
enrollment)

Administration PC*

LAN

Electric lock*

Electric lock*

Door control box* Access server*

Camera 3

BM-ET500

BM-ED500

POWER

ALARM S3

S2

S1

Wiegand
or RS-485

* The use of the Administration PC was not evaluated by UL.
* The use of electric lock was not evaluated by UL.
* The use of door control box was not evaluated by UL.
* General-purpose power supply must be a UL Listed access control power limited device.

• Keep the unit away from:

direct sunlight or light reflection.

incandescent or halogen lighting.

places where shadow appear over the front panel.

noise. (for example, places near air conditioners or ven-
tilators)

electricity.

outdoor places.

vibration. (It may cause invalid recognition or injury.)

• Do not place anything inside the space described in

the illustration.

• This unit is for indoor use only.
• This unit must be mounted horizontally on the wall.
• Determine the optimum mounting height. The recom-

mendation is between 1.38 m {54 in.} and 1.5 m {60 in.}
for enrollment/recognition effectiveness.

• Mount the bracket on the wall. Be sure to provide

access for video control and DC power from the control
unit.