Port-A-Cool PAC2K16HPVSFC User Manual
Page 14

BROnZE puMp (pAC2K36HZ or pAC2K48HZ)
SHAFT TYpE puMp (16” models)
pROBLEM
CHECK
SOLuTIOn
Pump motor will not run when
Power cord,
Reconnect power,
switch is turned on.
switches, circuit breaker, etc.
reset breaker.
Pump motor hums when
Object jammed into
Remove object.
switch is turned on,
impeller blade.
Prime pump.
but does not
pump water.
Air Locked.
Replace
Pump/Motor locked.
pump/motor.
Pump makes loud noise
Pump bearings.
Replace pump.
while running
Object in impeller housing.
Clear object.
Breaker trips or fuse blows
Pump motor locked.
Replace pump/motor.
when switch is turned on.
Pump will not run and power Switch making closure contact.
Replace switch.
is available and pump
is functional
Pump motor running but
Set screws on coupling.
Tighten set-screw /
pump is not turning.
Replace coupling.
pROBLEM
CHECK
SOLuTIOn
Pump motor will not run
Power cord,
Reconnect power
when switch is turned on.
switches, circuit breaker,
cord, reset breaker.
switch box, connections, etc.
or reconnect to switch box.
Pump motor hums when Object jammed into impeller blade.
Remove object.
switch is turned on, but
Air Locked.
Prime pump.
does not pump water.
Check disc that covers impeller
Attach disc securely
Pump motor locked.
Replace pump.
Pump makes loud noise
Pump bearings.
Replace pump.
while running.
Object in impeller housing.
Clear object.
Breaker trips or fuse blows
Pump motor locked.
Replace pump.
when switch is turned on.
Pump won’t run and power
Switch making closure contact.
Replace switch.
is available and
pump is functional.
27
2009 PORT-A-COOL® Unit Electric Models
14