4 external alarm in/out connection, External alarm in/out connection – Planet Technology DVR-1670 User Manual
Page 10
![background image](/manuals/185948/10/background.png)
External Alarm Input
4/8/16 Alarm in.
Relay Output
2/4 Alarm out
8
AC Input
100V~240VAC
2.4 External
Alarm
In/Out
Connection
Alarm input port
G (GND) Conenct the GND of sensor.
1~16 Alarm input, support normal open/normal close.
0 Reserved.
Alarm output
1G~4G 4 relay output.
Alarm output connection
Please note the usage of jumper JJ1. If you use DC, either of connections is OK. We suggest
you to use those DC under 12V, 1A.
If you use AC, please open the jumper. There are 4 jumpers (JJ1, JJ2, JJ3 and JJ4) in DVR
main board, corresponding with 4 alarm output. The default is closed.
Warning
If you use AC input for relay output, please open the jumpers.